BookTitleWATSON BIO LAB General Catalog

page
28/92

This page is an overview of WATSON BIO LAB General Catalog on page28
Move to the page after second(s).
Now go to the page by clicking "Open the e-Book" button.

WATSON BIO LAB General Catalog

ReadBook

Open e-Book in Flash Viewer

This e-Book is not available in your environment.

Summary

WATSON BIO LAB General Catalog

120-805C 1298-805RA122-805C130 mm1000μL 800μL 500μL 200μL 100μL 50μL1200 μL805Refill PlateSystem RackPCBulk1200μL, Extra Long Tip1200μL, Extra LongSystem Rack, Natural1200μL, Extra LongRefill Plate, NaturalEmpty Rack for # 805120-805C120-805CS1298-805RA122-805C122-805CS110-805CCat. No.1200μL, Extra Long Tip, Graduated, Natural1200μL, Extra Long Tip, Graduated, NaturalEmpty Rack for # 805 (1200 μL Extra Long)and 126 / 127-1200S1200μL, Extra Long Tip, Graduated, Natural1200μL, Extra Long Tip, Graduated, Natural1200μL, Extra Long Tip, Graduated, NaturalItemSystem Racked(PC)System Racked(PC)━Refill PlatedRefill PlatedBulkPackaging96 tips×10 racks10 racks96 tips×10 plates1000 tipsUnit5 units96 tips×10 racks96 tips×10 plates5 units5 units5 units5 units10 bagsCaseExtra LongIt reaches to the inner bottom of 15 mL / 50 mLcentrifuge tube. No concern of contamination ofthe pipettor’s nozzle with the solution and/orthe inner part of centrifuge tube.SterilizedSterilized・Watson NEXTY 100-1000μL / 1000μL(Fixed volume)・Eppendorf Reference/Research V 50-250μL(4910) / 100-1000μL・Gilson Pipetman P-1000 ・Finnpipette Digital 100-1000μL・Biohit Proline 100-1000μL ・Nichiryo Nichipet EX 100-1000μLPipette tip compatibility70680480580648.75 ㎜ 51.66 ㎜ 53.9 ㎜96.4 ㎜Example: Adjustment of heightThe level when dispensingwith 1000 μL on the pipette scale.NT-200y=36.46x2+19.83x25020015010050Targeted volume (y)00.00 0.50 1.00 1.50 2.00 2.50Volume to be corrected (x) Volume to be corrected (x)NT-10001200100080060040020000.00 2.00 4.00 6.00 8.00 10.00 12.00 14.00 16.00y=3.37x2+19.75x-19.75+ 19.752+4×3.37y2×3.3719.83 x= -19.83+ 2+4×36.46y2×36.46x=Formula for volume correctionNote: No adjustment is necessary for the tip # 502, 706, 804, or 806.Formula for volume correctionTargeted volume (y)PRECAUTIONS : When using the long tip or extra-long tipThe liquid is affected by pressure, dependent onthe size/length of the tip. Therefore when you use a certainpipette in combination with a long tip, it is necessary to adjustthe scale on the pipette tip’s height (=height of sample) inaccordance to the level to which liquid has been drawn in.If an 801* tip (250 μL) or an 805** tip (1200 μL) is used, it isnecessary to make adjustments to the scale by referring tothe adjustment values shown in the below figure.(Values obtained with the formula remain approximate.)Note: The shape/size of the following tips is identical.*Tip # 801: Tip # 200XS series**Tip # 805: Tip # 1200S seriesReal scaleGraduated Sterilized AutoclavableAC *:see below**Note:(*)Refill plate type is autoclavable after setting into tip rack.28 Pipette Tips Pipette TipsPipette Tips