BookTitleWATSON BIO LAB General Catalog

page
29/92

This page is an overview of WATSON BIO LAB General Catalog on page29
Move to the page after second(s).
Now go to the page by clicking "Open the e-Book" button.

WATSON BIO LAB General Catalog

ReadBook

Open e-Book in Flash Viewer

This e-Book is not available in your environment.

Summary

WATSON BIO LAB General Catalog

Edgeless Large-bore Tips5 mL401 5 mL 4 mL 3 mL 2 mL 1 mLReal scaleReal scaleReal scaleGraduated Sterilized AutoclavableACAutoclavableACSystem RackPCBulkBulkAutoclavableACBulk120-401C5000μL, System RackNatural1298-401RAEmpty Rack for # 4015000μL, 130 mm130 mm120-401C120-401CS1298-401RA110-401CCat. No.Empty Rack for # 401 (5000 μL)5000μL, Standard Tip, Graduated, Natural5000μL, Standard Tip, Graduated, Natural5000μL, Standard Tip, Graduated, NaturalItemSystem Racked(PC)System Racked(PC)━BulkPackaging24 tips×10 racks24 tips×10 racks10 racks250 tipsUnit5 units5 units5 units10 bagsCase113-743CCat. No.113-842CCat. No.Edgeless Large-bore Tip for 200μL, NaturalItemEdgeless Large-bore Tip for 1000μL, NaturalItem1000 tipsUnit1000 tipsUnitBulkPackagingBulkPackaging10 bagsCase10 bagsCase35.4~41.8 ㎜ (The length is different.)※tip inner diameterΦ1.35 ~ 2.00 ㎜Edgeless Large-bore Tip (200μL type for pipette connection)Edgeless Large-bore Tip (1000μL type for pipette connection)57.8~69.3 ㎜ (The length is different.)※tip inner diameterΦ2.40 ~ 4.50 ㎜The Edgeless bore tip has smooth rounded surfaceon the point of the tip by shortening the lengthof the tip which makes the inner diameter bigger.It is suitable for pipetting mouse embryo, hydra,nematode, retina cells, etc. not to damage suchsamples when aspirating and dispensing by pipette.The tip comes with various insidediameters.Select one that fits the size ofthe sample.Note: Since the diameter and length of the tip vary from tip to tip in a bulk supply,the actual volume may not be exactly as stable as 200 μL or 1000 μL.Therefore, please DO NOT set the aspiration volume of the pipette as 200 μL / 1000 μLbut set it much smaller than 200 μL / 1000 μL to avoid any accidental over-suction ofthe sample resulting in contamination inside the pipette.113-743C 113-842CSterilized・Watson NEXTY 50-5000μL / 5000μL (Fixed volume)・Gilson Pipetman P-5000・Socorex Acura 0.5 - 5 mLPipette tip compatibility・Watson NEXTY 2-20μL / 10-100μL / 20-200μL・Eppendorf Reference/Research V 2-20μL / 10-100μL(Multi) / 50(20)-200μL・Gilson Pipetman P-20 / P-100 / P-200・Finnpipette Digital 2-20μL / 5-50μL(Multi) / 10-100μL / 20-200μL・Biohit Proline 2-20μL / 5-50μL(Multi) / 10-100μL / 20-200μL・Nichiryo Nichipet EX 2-20μL / 10-100μL / 20-200μL / 5-50μL (Multi) / 40-200μL (Multi)Pipette tip compatibility・Watson NEXTY 100-1000μL・Eppendorf Reference/Research V 50-250μL(4910) / 100-1000μL・Gilson Pipetman P-1000 ・Finnpipette Digital 100-1000μL・Biohit Proline 100-1000μL ・Nichiryo Nichipet EX 100-1000μLPipette tip compatibilityPipette Tips 29Pipette TipsPipette Tips