Repetitive Pipette “Peggy”

No batteries, no charging needed! A handy and convenient manual Repetitive pipette

Simply set the dial scale and attach the serological pipette for effortless aspiration and dispensing.

Aspirate the sample all at once, dispense the necessary volume repetitively.

Aspiration volume setting dial

Aspiration can be set in every 1 mL for the range of 1 –13 mL.

  • ※Note: 13 mL can be dispensed in case that Watson 10 mL Serological Pipette is used.

Dispensing volume seting dial

Dispensing can be set in every 0.5 mL for setting range 0.5 –5 mL.

Flexible nozzle-angle

Adjustable nozzle angle in every 10 degrees up 50 degrees.

Simple maintenance

Nozzle cover: Autoclavable.

Joint packing: Autoclavable
Water stop filter: Replaceable

※Precaution in case of using5 mL serological pipette:
Please DO NOT set aspiration volume exceeding 5 mL in case that 5 mL serological pipette is used. It may cause an accidental liquid suction leading to malfunction on Peggy.

How to use

Aspiration

①Set the aspiration

volume using the aspiration-volume-setting dial.
Note: DO NOT set volume exceeding the volume of serological pipette.

②Attach the serological pipette to the Peggy nozzle.

※You can use 5 mL and 10 mL plastic serological pipettes from various manufacturers.

③Push the aspiration button slowly to aspirate the sample. After aspiration, slowly lift the Peggy out of the test tube.

  • If the aspiration button is pushed in before aspirating a sample, it results in insufficient aspiration. Make sure the aspiration button is in the original position by pushing dispensing button.
  • The movable range of the aspiration button is variable depending on the setting. The smaller the set volume is, the less the movable range is. Do not push in the aspiration button forcibly when it stops. It enables the protection system to unlock and change the dial setting.

Dispensing

①Set the dispensing volume using the dispensing-volume-setting dial.

②Push the dispensing button one by one. Hold down the dispensing button until the solution no longer comes out of the tip. Each time the button is pushed, the set volume is dispensed.

  • When you dispensing repeatedly, make sure the button comes back to the top position every time dispensing is completed.
  • When you dispensing higher volume, press the dispensing button slowly.
  • The aspiration button comes back to the original position as you push the dispensing button. Release your fingers from the aspiration button while operating the dispensing button.
Cat. No.ItemAspiration volume
max
Aspiration volume
min
dispensing volume
max
dispensing volume
min
Packaging
PG-01PEGGY-01
Repetitive Pipette “Peggy”
13mL1mL5mL0.5mL1 unit

Consumables for Peggy

For Peggy’s Heavy Users!
No need to worry about wear and tear. We have replacement parts available.

Replacement parts can be autoclaved.
To reduce the stroke load during repeated use, please use the ‘Joint Packing (non-filter type)’.

Joint packing

Joint packing
(non-filter type)

Water stop filter

If you want to reduce the load on the stroke during repeated use

You can reduce it by replacing the included joint packing with the ‘non-filter type’ one after removing the water stop filter.

Rotate the nozzle tip in the direction of the 35-degree arrow and remove it.

Pull out the joint packing and the water stop filter.

Replace the joint packing with the ‘non-filter type’ one, and assemble the nozzle tip.

When removing the water stop filter, it is not possible to prevent excessive intake of specimen fluid into the main body due to incorrect settings. Before suction, please always ensure that the suction capacity setting matches the capacity of your pipette.

Cat. No.ItemUnit
PG-01-JP1Joint packing for Peggy1 piece
PG-01-JP2Joint packing for Peggy (non filter type)1 piece
PG-01-SF1Replaceable water stop filter for Peggy5 pieces / bag